QuickTrace M‑8000
Cold Vapor Atomic Fluorescence (CVAF) Mercury Analyzer

The QuickTrace® M-8000 Cold Vapor Atomic Fluorescence (CVAF) mercury analyzer is ideal for ultra-trace to sub-mg/L mercury quantitation. Due to the high sensitivity of the M-8000, it easily achieves the ultra-trace detection limit of <0.05 ng/L total mercury that is demanded by customers following EPA method 1631. The QuickTrace® M-8000 is also versatile enough to analyze samples >400 µg/L without dilution in a research or industrial setting.

Consulting
021-62088010
Update time:2024-10-17
Current location : HomeProductsSpectrum > Automated Mercury Systems > Cold Vapor Atomic Fluorescence (CVAF) Mercury Analyzer
 

Overview

The QuickTrace® M-8000 Cold Vapor Atomic Fluorescence (CVAF) mercury analyzer is ideal for ultra-trace to sub-mg/L mercury quantitation. Due to the high sensitivity of the M-8000, it easily achieves the ultra-trace detection limit of <0.05 ng/L total mercury that is demanded by customers following EPA method 1631. The QuickTrace® M-8000 is also versatile enough to analyze samples >400 µg/L without dilution in a research or industrial setting. 

The QuickTrace® M-8000 mercury analyzer supports three software selected modes of operation (without hardware or tubing configuration changes) to quickly match your analytical requirements. When a method is selected in the software, the instrument switches between ultra-trace analysis and low mg/L analysis, saving method configuration time and eliminating costly mistakes.


 

Features

The triple mode, no enrichment, single or double gold amalgamation QuickTrace M-8000 CVAF is the system of choice for labs wanting to meet the most stringent reporting limits for academic research or enhanced waste discharge limits demanded by the “Clean Water Act”.

  • Non-foaming Gas Liquid Separator (GLS) with overflow prevention system

  • Automatic end of run and inactivity standby routines

  • ≤ 0.05 ng/L instrument detection limits

  • Advanced contamination control, over range and smart rinse features

  • Intuitive gas controls eliminating air infusion into the system during sample probe movements during mode 2 and 3 analysis

  • EPA 1631 and EPA 245.7 compliant (gold amalgamation modes)

  • “Smart Rack” technology

  • 12-roller 4-channel peristaltic pump

  • Sample volume 0.5 mL to > 50 mL

  • Unlimited QC sample positions


 

standards

  • EPA Method 245.7

  • EPA Method 1631

  • SW 846-7474

  • EU Methods: Din ISO 16772

  • EN-12338

  • ISO 17852