CN
Clora Online
Process MWDXRF Chlorine Analyzer

Chlorine is often present in crude oils and the concentration can vary greatly depending on the origin. If not removed, chlorine can react to form highly corrosive hydrochloric acid in areas such as crude tower overheads, leading to serious operational issues, economic loss, and safety concerns. The need for a reliable online chlorine analyzer for refining process control is more important than ever. Clora Online (Clora OL) complies with the ASTM D7536 method and delivers continuous chlorine analysis to monitor plant equipment corrosion. By monitoring desalted crude, a plant can optimize performance and immediately see the impacts of crude changes (including organic chlorides). Additionally, monitoring overhead water can provide the necessary feedback for chemical feed.

Consulting
021-62088010
Update time:2020-05-26
Current location : HomeProductsSpectrum > Element analyzer > Process MWDXRF Chlorine Analyzer
 

Overview

Chlorine is often present in crude oils and the concentration can vary greatly depending on the origin. If not removed, chlorine can react to form highly corrosive hydrochloric acid in areas such as crude tower overheads, leading to serious operational issues, economic loss, and safety concerns. The need for a reliable online chlorine analyzer for refining process control is more important than ever. Clora Online (Clora OL) complies with the ASTM D7536 method and delivers continuous chlorine analysis to monitor plant equipment corrosion. By monitoring desalted crude, a plant can optimize performance and immediately see the impacts of crude changes (including organic chlorides). Additionally, monitoring overhead water can provide the necessary feedback for chemical feed.

 

Features

  • Using MWD XRF monochromatic wavelength dispersive X-ray fluorescence technology, ultra-low background

  • LOD: 0.2ppm (Hydrocarbon), 0.6ppm (Aqueous)

  • Dynamic Range:0.2 ppm – 3000 ppm

  • For most application purposes, one calibration curve over full dynamic range

  • Robust industrial design: wall mounted or stand alone

  • Low Maintenance: no consumable liquids, gasses, combustion, or sample conversion

  • ATEX Zone 1 and NEC Cl | Div 2 Certified

 

standards

  • ASTM D7536-16 Standard Test Method for Chlorine in Aromatics by Monochromatic Wavelength Dispersive X-ray Fluorescence Spectrometry

  • ASTM D4929-19 Standard Test Method for Determination of Organic Chloride Content in Crude Oil (procedure C)

  • SH/T 0977-2019 Using Monochromatic wavelength dispersive X-ray fluorescence spectrometr to determine Light liquid fuels determination of chlorine content

 

application field

  • Pipeline terminals

    Pipeline terminals

    interface cuts, custody transfer acceptance, and tank contamination prevention

  • Refinery

    Refinery

    for hydrofining unit and blending system

  • Pipeline terminals

    Pipeline terminals

    interface cuts, custody transfer acceptance, and tank contamination prevention

  • Refinery

    Refinery

    for hydrofining unit and blending system

Service Hotline

021-62088010
  • Address : 4F, Building 88, Zhihuiyuan, No. 1199, Qinzhou North Road, Xuhui District, Shanghai, 200233
  • Fax : 021-62191934

Other contact information